Output | Voltage Tolerance | ±5% |
Line Regulation | ±0.5% |
Load Regulation | ±2% |
Setup、Rise Time | 500ms,30ms/220Vac (Full load) |
Hold up time | 200ms/220Vac (Full load) |
Input | Voltage Range | 100~240Vac |
Frequency Range | 50/60Hz |
Efficiency | 85% |
Ac Current | 0.8A/220Vac |
Inrush Current | Cold Start:50A/220Vac |
Leakage Current | 3.5mA |
Protection | Over Load | Rated output power: 110%~135% |
Protection type:Hiccup mode,recovers automatically after fault condition is removed |
Over Voltage | Rated output Voltage:115%~150% |
Protection type:Hiccup mode,recovers automatically after fault condition is removed |
Over temperature protection | Protection type:crystal internal contact temperature exceeds 140℃,turn off the output,when the temperature returns to normal automatic recovery |
Short circuit protection | Protection type:PWM control shutting down and output,it will work after exception is solved |
Environment | Working Temp | -10℃~60℃ |
Working Humidity | 20~90%RH,non-condensing |
Storage Temp、Humidity | -30℃~75℃ 10~98%RH,non-condensing |
Temp. Coefficient | ±0.03%/℃(0~50℃) |
Vibration | 10~500Hz,5G , 10Min/1 cycle,period for 60min,each along X,Y,Z axes |
Safety & EMC | Safety Standards | GB4943,EN60950 |
Withstand Voltage | I/P-O/P:1.5KVAC I/P-FG:1KVAC O/P-FG:1KVAC |
solation Resistance | I/P-O/P I/P-FG O/P-FG:100M Ohms/500VDC/25℃/70%RH |
EMI Conduction Radiation | Compliance to :EN55022, EN61000-3-2,3, FCC part15,GB9254 class B,GB17625.1 |
EMS Immunity | Compliance to :EN61000-4-2,3,4,5,6,8,11,light industry level, criteria A |
Others | MTBF | ≥1415.6Khrs |
Dimension | 59*25*40mm(L*W*H) |
Packing | 0.04Kg 500pcs/20Kg |