特征
設(shè)計(jì)用于提供8種現(xiàn)場(chǎng)可編程功能,可控制單刀雙擲繼電器,定時(shí)時(shí)間隔范圍為1秒至99天
Program Modes 編程模式
One shot - Applying trigger activates relay for selected time. Trigger input must be removed & re-applied to re-active.
一次性 - 應(yīng)用觸發(fā)激活繼電器選擇的時(shí)間。 必須刪除觸發(fā)器輸入并重新應(yīng)用才能重新激活。
Retriggerable - As for One Shot, except where input is retriggered, the timer starts again.
可重新觸發(fā) - 對(duì)于單次拍攝,除了重新觸發(fā)輸入,定時(shí)器重新開(kāi)始。
Strobe - Requires momentary trigger to be applied, relay will activate for programmed time.
頻閃 - 需要瞬時(shí)觸發(fā),繼電器將激活編程時(shí)間。
Clutch Relay - Applying trigger causes relay to change state. Removing and re-applying trigger forces relay to change state. No timing function in this mode.
離合器繼電器 - 應(yīng)用觸發(fā)器使繼電器改變狀態(tài)。 去除和重新施加觸發(fā)力繼電器改變狀態(tài)。 此模式下無(wú)定時(shí)功能。
Programmed Pulse - Applying trigger causes relay to operate for one second at programmed intervals. Set intervals on SW2, SW3 & SW4. Operation ceases when trigger is removed.
編程脈沖 - 應(yīng)用觸發(fā)使繼電器以編程間隔運(yùn)行一秒鐘。 在SW2,SW3和SW4上設(shè)置間隔。 觸發(fā)器被移除后,操作停止。
Debounce - Applying trigger causes relay to activate for programmed time. Relay remains activated until timeout regardless of trigger being removed. If input remains triggered after timeout, relay remains activated until trigger is removed.
去抖 - 應(yīng)用觸發(fā)使繼電器激活編程時(shí)間。 繼電器保持激活直到超時(shí),無(wú)論觸發(fā)被移除。 如果輸入在超時(shí)后保持觸發(fā),則繼電器保持激活,直到觸發(fā)被移除。
Stand-Off Timer - Ideal for DOTL (Door Open Too Long) alarms. Timing commences when trigger is applied. If trigger is removed before timeout, relay will not activate. If trigger remains after timeout, relay will activate.
待機(jī)定時(shí)器 - 適用于DOTL(門(mén)打開(kāi)太長(zhǎng))報(bào)警。 啟動(dòng)觸發(fā)時(shí)開(kāi)始計(jì)時(shí)。 如果觸發(fā)器在超時(shí)之前被刪除,繼電器將不會(huì)激活。 如果超時(shí)后觸發(fā)保持,則繼電器將激活。
Fail Secure - The relay does not change state during power failure.
故障牢固 - 斷電時(shí)繼電器不改變狀態(tài)。
Fail Safe - The relay is energised when the trigger is not active. Relay will de-energise (e.g. releasing power to door locks) during a power failure.